GC-2010 Pro

The GC-2010 Pro represents a new generation in Routine GC. Fast oven heating and cooling reduces the analysis time and allow high sample throughput. Based on high-end GC technology, it combines easy operation with efficient analysis and excellence in sensitivity and precision.

Category:
Producer:

Product Description

The GC-2010 Pro represents a new generation in Routine GC. Fast oven heating and cooling reduces the analysis time and allow high sample throughput. Based on high-end GC technology, it combines easy operation with efficient analysis and excellence in sensitivity and precision.

Technical specifications

 

 

Achieving excellent reproducibility

Analysis of Grob Test Mixture (Solvent: acetone, each 100 ppm)Analysis of Grob Test Mixture (Solvent: acetone, each 100 ppm)

All units including the column oven, flow controller and sample injection unit are comprehensively optimized at the design stage to achieve world-class repeatability of peak area and peak height. The large vaporization capacity ensures excellent repeatability, even when using solvents that are highly volatile upon injection, such as acetone. Long-term stability of retention time is realized by the new room compensation technology built into the advanced flow controller (AFC).

 

 

High-speed analysis

High-speed analysis with narrow bore capillary columns reduces analysis time and improves sample throughput. GC-2010 Pro has excellent flow and pressure control system, which can meet the requirements of rapid analysis with conventional configuration and effectively improve the analysis efficiency.

 

Rapid oven heating / cooling

GC-2010 Pro incorporates a double-jet cooling system, which enables the reduction of cooling time from 450℃ to 50℃ in 3.4min, realizing more efficient and rapid cooling. In addition, with the ability of rapid heating, GC-2010 Pro can significantly reduce the analysis time.

 

Constant linear velocity mode quickly determines separation conditions

The constant linear velocity mode related to the separation performance is recommended for the carrier gas control and can obtain the optimum separation conditions in the shortest time compared with the previous control method by setting the column inlet pressure and flow.

 

Gas saver function reduces helium consumption

Reducing running cost by gas saving is an important issue in GC operation. GC-2010 Pro reduces gas consumption by decreasing of split ratio after injection as well as automatic shutdown functions after finishing all analysis.

 

High-performance injection unit series

In order to obtain good data, it is necessary to select an appropriate injection method according to the analysis purpose and sample. GC-2010 Pro can select the most suitable injection method from three injection units.

SPL

  • Injection unit used for split/splitless injection of capillary column.
  • Standard configuration, namely, AFC with high performance, supports high-speed GC with narrow bore capillary columns.
  • Gas saver function reduces split gas consumption.
  • Permits high-pressure injection mode.
  • The purge flow can be set and changed to achieve more efficient sample purge and prevent cross contamination.

WBI

  • Used for full injection of wide bore capillary columns above 0.45mm.
  • Septum purge flow channel prevents solvent tailing.
  • Uses the same glass inserts as splitless analysis to simplify use.
    (Patented)

Small and high-sensitivity detector series

The full range of high-sensitivity detectors supports a wide variety of application analyses. Each detector is equipped with an advanced pressure controller (APC) that digitally sets the gas parameters of each detector. To ensure secure use of hydrogen the connector joints have reverse threads to prevent incorrect pipe connections (FID, FPD, FTD).

 

Automatic injection system

AOC-20 series, Automatic injection system
  • Easy to install and remove.
  • AOC-20s can support analysis of up to 150 samples (1.5mL sample bottles).
  • A dual injection system can be configured with a combination off two AOC-20i injectors. Two-line simultaneous injection doubles the sample throughput to improve productivity.

Industry Leading Detector Sensitivity

Responding to the ever increasing demands for trace level analysis, all detectors of GC-2010 Pro realize high sensitivity in miniaturization design. The new flame photometric detector (FPD) and flame ionization detector (FID) show significantly increased sensitivity.

 

Flame ionization detector FID

High-sensitivity has been achieved by thorough cleaning of detector gas lines and the latest noise-reduction technology.

 

Flame photometric detector FPD

It achieves compact design and improves the flame stability by improving the nozzle form. In addition, the "dual-focus system" achieves excellent ultra high sensitivity. The dual-focus system adds a lens to the interference filter for efficient light collection at the photomultiplier light receptor.