DSC-60 Plus/60A Plus

DSC-60 Plus/60A Plus Differential Scanning Calorimeter

 

The DSC-60 Plus is an indispensable thermal analyzer for materials characterization in R&D and quality control applications in such areas as polymers, pharmaceuticals, electronic parts, foods, etc . It offers the sensitivity and easy operation required for the development of high-performance, highly functional new materials.

  • Temperature range: -140 – 600 °C
  • Calorimetric measurement range: ±150 mW
  • Noise level: 0.5µW
  • Liquid nitrogen cooling option

Category:
Producer:

Product Description

DSC-60 Plus/60A Plus Differential Scanning Calorimeter

 

The DSC-60 Plus is an indispensable thermal analyzer for materials characterization in R&D and quality control applications in such areas as polymers, pharmaceuticals, electronic parts, foods, etc . It offers the sensitivity and easy operation required for the development of high-performance, highly functional new materials.

  • Temperature range: -140 – 600 °C
  • Calorimetric measurement range: ±150 mW
  • Noise level: 0.5µW
  • Liquid nitrogen cooling option

Technical specifications

1. High-Performance General-Purpose DSC

  • High sensitivity and high resolution
  • Stable baseline from ultra-low to high temperatures

The new detector in the DSC-60 Plus series and the unique furnace construction achieve a stable baseline across the entire measured temperature range (-140-600°C) as well as top-class calorimetric sensitivity for a DSC. It features a wide dynami measurement range of ±150 mW.

2. Diverse Measurements by Simple Operations

  • Cooling chamber installed as standard
  • Sample loading temperature function is convenient for sample replacement

The liquid-nitrogen cooling chamber permits easy measurements below room temperature without having to install special accessories. The sample loading temperature function enables quick sample change during sequential analysis without moisture codensation.

3. Complies with Analytical Laboratory Regulations

The DSC-60 Plus series complies with various guidelines involving analytical laboratories, such as the PIC/S GMP guidelines, and electronic record/electronic signature (ER/ES) regulations, including the US FDA 21 CFR Part11. In addition, it is compatible with other analytical instruments and connected network systems.

Specifications

  Differential Scanning Calorimeter
DSC-60 Plus
Automatic Differential Scanning Calorimeter
DSC-60A Plus
 Temperature range -140 to 600°C *1 (With standard cooling chamber and using liquid nitrogen )
 Measurement range ±150mW
 Size W:320 x H:500 x D:500 (mm)
 Weight 28kg 31kg