HS-20 Headspace

A Revolutionary System Aimed at Performance and Ease of Use
The HS-20 Series is the optimal solution for volatile component analysis.
Its superior performance and user-friendly design support all types of analyses, from research to quality control.

HS-20 / HS-10 Headspace

 

HS-20 and HS-10 series headspace systems, are ideal solutions for volatile compound analyses such as VOC, residual solvent, aroma, fragnance, alcohol.  

  • High repeatability
  • Low carry-over
  • High temperature adaptation
  • Trap and low temperature options (HS-20 model)
  • Graduated vial mixing
  
Functions / Models HS-20 HS-10
Sample capacity 90 20
Temperature Up to 300 oC Up to 225 oC
Trap and low temperature options HS-20 Trap and HS-20LT Models -
Vial mixing 5 steps 3 steps

 
 

Product Description

A Revolutionary System Aimed at Performance and Ease of Use
The HS-20 Series is the optimal solution for volatile component analysis.
Its superior performance and user-friendly design support all types of analyses, from research to quality control.

HS-20 / HS-10 Headspace

 

HS-20 and HS-10 series headspace systems, are ideal solutions for volatile compound analyses such as VOC, residual solvent, aroma, fragnance, alcohol.  

  • High repeatability
  • Low carry-over
  • High temperature adaptation
  • Trap and low temperature options (HS-20 model)
  • Graduated vial mixing
  
Functions / Models HS-20 HS-10
Sample capacity 90 20
Temperature Up to 300 oC Up to 225 oC
Trap and low temperature options HS-20 Trap and HS-20LT Models -
Vial mixing 5 steps 3 steps

 
 

Technical specifications

 

1. Excellent Performance

High reproducibility and low carryover ensure reliablequantitation. In addition, an oven with a maximum temperature of 300 °C enables analysis of high-boiling compounds.

High Reproducibility 
The HS-20 Series achieves high reproducibility through both high-accuracy flow rate control via the pneumatic flow controller (Advanced Flow Control: AFC system) and a mechanism that allows sample vial to enter the oven from the bottom.
Consequently, this system minimizes heat loss, and maintains high thermal stability during overlap analyses.

High Reproducibility

Low Carryover 
Keeping the sample line inert and as short as possible results in extremely low carryover. No residue is left, even with acetic acid and other polar compounds,enabling highly reliable analysis. (Patent pending)

Low Carryover

High-Temperature Compatibility 
With an oven configurable up to 300 °C and a simple, inert sample line, the HS-20 Series allows the analysis of high-boiling compounds.
Cyclic siloxane is a raw silicone material, trace quantities of which remain in oils, liquid rubber, and other products.
Because cyclic siloxane is volatile, it could potentially cause problems with contacts in electronic parts, so controlling its concentration is very important. The HS-20 Series makes it possible to measure everything from cyclic siloxane to phthalate esters under the same conditions.

High-Temperature Compatibility


 

2. User-Friendly Design

Easily place samples in the tray with the user-friendly design. Also, the needle, sample loop, trap, and other consumables can easily be replaced from the top of the instrument.

User-friendly sample tray

User-friendly sample tray 
The HS-20 sample tray is 20 cm higher than the desk,enabling it to be seen at all times. This makes sample placement easy.
In addition, 10 mL and 20 mL vials can be placed and analyzed simultaneously without the need for special attachments.
Furthermore, the optional barcode reader allows samples to be controlled using barcodes.

Easy Maintenance

Easy Maintenance 
The HS-20 Series has been designed to enable sample loop and needle replacement and other maintenance work to be performed easily from the top of the instrument.
Even if sample lines become contaminated by high-concentration samples, the piping alone can now be replaced.
Also, the capillary column joints are shared with the GC sample injection unit, enabling easy column replacement.
This superior design minimizes downtime during maintenance and improves laboratory productivity.



 

3. Excellent Expandability

With the trap model, concentrating the headspace gas enables the analysis of ultra-trace components, such as gases released from parts and materials.
The optional barcode reader enables samples to be controlled via a chromatography data system.

Sample Concentration 
The HS-20 trap model is equipped with an electronic cooling trap that concentrates the headspace gas, enabling high-sensitivity analysis. By using hydrophobic Tenax, the trap enables the analysis of low-boiling compounds by concentrating them to high-boiling compounds in samples containing moisture.
Method files make it easy to switch between trap and conventional modes, in which a sample loop is used. The two modes can be combined even in continuous analysis via batch processing.