Features of Double Chamber Incubator (Natural Convection & Low Temp.) (INC820)
Features of Double Chamber Incubator (Natural Convection & Low Temp.) (INC820)
Specifications
| Item Code | 211210 |
|---|---|
| Model | INC820 |
| System (Upper Chamber) | Natural convection, Air jacket |
| Operating Temp. Range(Upper Chamber) | Room temp.+5℃~80℃ |
| Temp. Adjustment Accuracy (Upper Chamber) | ±0.5℃(at 37℃) |
| Temp. Distribution Accuracy (Upper Chamber) | ±1℃(at 37℃) |
| Interior | Stainless Steel |
| Heater (Upper Chamber) | Ferrochrome Heater |
| Heat Insulation Material (Upper Chamber) | Glass Wool |
| Heater Power (Upper Chamber) | 400W |
| Cable Port (Upper Chamber) | 30mm ID (Right side from the front) |
| Exhaust Port (Upper Chamber) | 30mm(with Damper), 2 ports on the top |
| Controller (Upper Chamber) | VS3 Type, Fixed operation temperature controller |
| Operation Function (Upper Chamber) | Fixed temp., Quick auto stop, Auto stop, Auto start operation |
| Internal Dimensions (Upper Chamber) | 600×530×500mm |
| Internal Capacity (Upper Chamber) | 150L |
| Shelf Step/ Pitch (Upper Chamber) | 13 steps / 30mm |
| Standard Shelf / Support (Upper Chamber) | 2 shelves/4 suppots |
| System (Lower Chmber) | Forced convection |
| Operating Temp. Range(Lower Chamber) | 4℃~50℃ |
| Temp. Adjustment Accuracy (Lower Chamber) | ±0.3℃(at continuous refrigeration) |
| Temp. Distribution Accuracy (Lower Chamber) | ±1℃(at continuous refrigeration) |
| Interior | Stainless Steel |
| Heater (Lower Chamber) | Ferrochrome Heater |
| Heat Insulation Material (Lower Chamber) | Stylene foam (Non-freon) |
| Heater Power (Lower Chamber) | 550W |
| Blower (Lower Chamber) | Axial fan |
| Refrigerator (Lower Chamber) | Air cooling, 250W |
| Refrigerant (Lower Chamber) | R404A |
| Defrost Operation (Lower Chamber) | Manual / Cycle |
| Cable Port (Lower Chamber) | 30mm ID (Right side from the front) |
| Controller (Lower Chamber) | VS4 Type Program operation temp. controller |
| Operation Function (Lower Chamber) | Program operation(30 steps ×1、15 steps×2、10 steps×3), Fixed temp. operation, Quick auto stop, Auto stop, Auto start |
| Safety Device (Lower Chamber) | Self-diagnostic functions(Temp. sensor error, Heater disconnection, SSR short-circuit, Main relay error, Automatic overheat prevention), Key-lock, Over current ELB, Overheat preventive device |
| Interior (Lower Chamber) | 600×477×500mm |
| Internal Capacity | 143L |
| Shelf support step number/pitch | 13 steps / 30mm |
| Shelf / Support | 3 shelves/6 pcs. |
| Sensor | Pt100Ω |
| Option | RS485 Terminal, Recorder contact terminal, Alarm terminal |
| Shelf Loading Capacity | Approx. 15kg/ shelf |
| Door Key | 1 pc. each |
| External dimensions(W×D×H mm) | 710×656×1792mm |
| Power Source | AC115/220V Single phase |
| Weight | 160kg |