LCMS-8050

LCMS-8050 Liquid Chromatograph Triple Quadrupole Mass Spectrometer (LCMSMS)

 

Continuing the evolution of Shimadzu's UF technology. Shimadzu introduces LCMS-8050 Triple Quadrupole Mass Spectrometer offering unparalleled measurement speed and high-sensitivity performance.

  • High sensitivity quantitation delivered at high speed
  • High speed scanning (UFscanning)
  • High sensitivity and Positive / Negative Ionization Switching Technology (UFswitching)
  • High sensitivity and high speed MRM (UF-MRM)
  • Patented ultra fast technologies (UFMS)
  • Method packages and databases (Pesticides, Forensic Tox, Veterinary, Met ID and more)

Product Description

LCMS-8050 Liquid Chromatograph Triple Quadrupole Mass Spectrometer (LCMSMS)

 

Continuing the evolution of Shimadzu's UF technology. Shimadzu introduces LCMS-8050 Triple Quadrupole Mass Spectrometer offering unparalleled measurement speed and high-sensitivity performance.

  • High sensitivity quantitation delivered at high speed
  • High speed scanning (UFscanning)
  • High sensitivity and Positive / Negative Ionization Switching Technology (UFswitching)
  • High sensitivity and high speed MRM (UF-MRM)
  • Patented ultra fast technologies (UFMS)
  • Method packages and databases (Pesticides, Forensic Tox, Veterinary, Met ID and more)

Technical specifications

UFsensitivity

UFscanning

High-Sensitivity & High-Speed Scanning at 30,000 u/sec

Simultaneous Quantitative and Qualitative Analysis
Simultaneous High-Speed Screening of 12 Toxicological Drugs

The LCMS-8050 is capable of simultaneously obtaining both qualitative and quantitative information in a single analysis. Acquisition occurs so rapidly that MS/MS scans and MRM measurements can be performed concurrently while maintaining quantitative accuracy. MS/MS scans are usable and reliable because even at 30,000 u/sec, Shimadzu uses a 0.1 u scan step.

UFscanning

MRM Triggered Product Ion Scanning of a Mixture of 12 Benzodiazepines (1 ng/mL each)

UFswitching

High-Sensitivity & High-Speed Positive/Negative Ionization Switching in 5 msec

Just One Minute per Analysis
A Case Study Using High-Speed Positive/Negative Ionization Switching

When performing simultaneous positive/negative ion measurements of multiple components, the proper acquisition of sharp UHPLC peaks depends on rapid polarity switching. The LCMS-8050 minimizes losses due to polarity switching and ensures the collection of sufficient data points for even the narrow peaks obtained with UHPLC, recording accurate peak shapes and allowing excellent reproducibility.

UFswitching

UF-MRM

High-Sensitivity & High-Speed MRM at 555 ch/sec

Detect Target Compounds at Trace-Level Concentrations
Simultaneous Analysis of 29 Pesticides for Water Quality Analysis

The LCMS-8050 is capable of simultaneously acquiring 555 MRM transitions per second while maintaining accuracy and precision. Sufficient data points can be collected for quantitation ions, reference ions, and internal standard ions even in chromatographic regions with unresolved peaks. The high sensitivity of the LCMS-8050 allows for trace-level analysis, such as pesticides in drinking water, without the need for sample pre-concentration. This high sensitivity is maintained even when monitoring numerous MRM channels.

Video

PDF

Download PDF