GC-2025 adopts the split/splitless injection unit (SPL), flame ionization detector (FID), and well-proven electronic flow controllers (AFC/APC) for carrier gas and detector gas control electronic flow controllers (AFC/APC) are installed as standard.

Compact Design Accepts Commercial Capillary Columns. The FID minimum detectable limit of 2 pgC/s offers high sensitivity for trace analysis.  Energy savings: 30% reduction as compared to the previous model.
 

Category:
Producer:

Product Description

 

GC-2025 adopts the split/splitless injection unit (SPL), flame ionization detector (FID), and well-proven electronic flow controllers (AFC/APC) for carrier gas and detector gas control electronic flow controllers (AFC/APC) are installed as standard.

Compact Design Accepts Commercial Capillary Columns. The FID minimum detectable limit of 2 pgC/s offers high sensitivity for trace analysis.  Energy savings: 30% reduction as compared to the previous model.
 

Technical specifications

GC-2025

Energy-Saving Gas Chromatograph

Shimadzu's new-generation GC-2025 capillary gas chromatograph minimizes environmental impact by reducing power and carrier gas consumption while retaining the performance capabilities required for capillary analysis.

The GC-2025 incorporates a digital flow controller that controls both the carrier and detector gases and a newly designed energy-saving column oven that features small volume and less heating loss, realizing a dramatic improvement in operation costs.

The compact GC-2025 is the gas chromatograph for environmentally friendly, high value performance.

Eco-Friendly

Comparison of Power Consumption

Comparison of Power Consumption Per Analysis Cycle

The eco-friendly GC-2025 significantly cuts electric power costs compared to previous models to reduce the burden on the environment.
Heat losses are significantly reduced through high-performance insulation and a smaller oven size to reduce the heating requirements. In addition, it incorporates an energy-saving heater to further cut power costs.
Power consumption is reduced by 30% for programmed temperature analysis in comparison to other GC models.
(The actual power consumption depends on the ambient temperature during analysis.)
 

Compact, All-in-One Design

In recent years, there has been an increasing demand for instruments with a smaller installation footprint to more effectively utilize laboratory space. The GC-2025 meets this requirement while incorporating all the functions required for normal capillary analysis.

Comparison of GC (Top View)

Comparison of GC (Top View)

Units for Normal Analysis Crowded into a Compact Space

The split/splitless injection unit (SPL), flame ionization detector (FID), and electronic flow controllers (AFC/APC) are installed as standard.