Features of Economical Incubator (Natural Convection, Slim Type) (ICS200)
Features of Economical Incubator (Natural Convection, Slim Type) (ICS200)
Specifications
Product Code | Model | Convection Type | Operating Temp. Range | Temp. Adjustment Accuracy | Temp. Distribution Accuracy | Time to Reach to Max. Temp. | Exterior | Heat Isolation Material | Heater | Door | Temp. Controller | Timer | Temp./Timer Display | Temp. Sensor | Operating Function | Operation Panel | Additional Function | Safety Countermeasure | Internal dimensions(W×D×H mm) | External dimensions(W×D×H mm) | Power supply | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
211105 | ICS200 | Air Jacket Type | Room Temp. +5 to 70deg.C | ±1deg.C (at 37deg.C) | ±1deg.C (at 37deg.C) | Approx. 60min. | Steel, Baked Paint Finish 0.8t | Rock Wool / Styrene Foam | Iron Chrome Wire Heater, 150W | Chrome-free electrogalvanized steel plate with melamine resin baking finish with Double Glass Observation Window | PID Control by Micro Computer | 0 to 999.9hrs. | LED Digital Display | Platinum resistance thermometer Pt100Ω | Fixed Operation (Automatic Start and Stop by Timer Setting) | Sheet Key (LED: Temp., Timer / Lamp: Heater, Temp. Abnormal) Main Switch (Electric Leakage Breaker) | Calibration Off set function, Power failure return mode | Independent Overheat Prevention by Liquid Pressure Type, Individual Overheat Prevention, Heater Wire Broken/Sensor Input Alarm, Electric Leakage Breaker, Key Lock Function | 240×250×340mm | 320×340×685mm | AC220V 0.7A Single-phase with step down transformer |
20kg |
211106 | ICS300 | Air Jacket Type | Room Temp. +5 to 70deg.C | ±1deg.C (at 37deg.C) | ±1deg.C (at 37deg.C) | Approx. 60min. | Steel, Baked Paint Finish 0.8t | Rock Wool / Styrene Foam | Iron Chrome Wire Heater, 250W | Chrome-free electrogalvanized steel plate with melamine resin baking finish with Double Glass Observation Window | PID Control by Micro Computer | 0 to 999.9hrs. | LED Digital Display | Platinum resistance thermometer Pt100Ω | Fixed Operation (Automatic Start and Stop by Timer Setting) | Sheet Key (LED: Temp., Timer / Lamp: Heater, Temp. Abnormal) Main Switch (Electric Leakage Breaker) | Calibration Off set function, Power failure return mode | Independent Overheat Prevention by Liquid Pressure Type, Individual Overheat Prevention, Heater Wire Broken/Sensor Input Alarm, Electric Leakage Breaker, Key Lock Function | 300×350×530mm | 380×440×875mm | AC220V 1.2A Single-phase with step down transformer |
30kg |